MakeModel Ch.SymptomProblem SolutionSolutionBy:
ITTPico S3
Dead apart from brief led flicker at sw onLOPTx
ITTPico S3
Dead - life restored if scan coils dis'dWidth control coil on scan coils has shorted turns
ITTPico S2
Dead - no relay click or displayMains st/by tfmr o/c pri
ITTPico S2
Dead - no relay click at switch on.Standby mains transformer primary winding o/c.
ITTPico S
St/by onlyrelay clicks at sw on but no HT to LOP Tr; C701 10µ 350v faulty
ITTPico S
Pulling/bouncing/int loss of soundC212 10µ 50v in CMR800 (top of can)
ITTPico S
No soundR1075 3R3 safety res o/c; C229 220µ s/c
ITTPico S
Misty pic - poor col with red flaringEarthing ring on crt base shorting to cathodes
ITTPico S
Int dead when heated115v HT still present; dry joints LOP tr
ITTPico S
Display shows "88"SAA1292 chip faulty - caused by dry joints esp on C10 1000µ
ITTPico S
Dead.Check small LT transformer for o/c.
ITTPico S
dead2A fuse on front panel o/c; degauss therm caused it
ITTPico S
Blank raster with line tearing - sound intC524 10µ
ITTPico S
Bad hum bar & no soundReplace 4 x 1N4007 mains rects
ITTCT3325 Pico S
No colour after few hours.T1410 in tuner control unit ( IFB351 )
ITTCT3315 Pico S
Dark picture.270k resistor in 1st anode supply.
ITTCP3106 Pico S
Frame - reduced.If IC401 pin 9 down to 19v suspect LOPTX.
ITT PICO S3
STBY LED FLICKERS BUT DEAD . PIN 4 LOPTX REMOVED PLOPTX US
ITT PICO S3
DEAD IF SCAN COILS DISCONNECTED TRIES TO RUNWIDTH CCT ON SCAN COILS SC